Retraction Assembly
- Low Pressure with Security Chain, 316, 316L Stainless Steel (MWP 125 psi)
- Low Pressure: 316, 316L Stainless Steel (MWP 50 psi)
- Medium Pressure: 316, 316L Stainless Steel (MWP 500 psi)
Insertion 'U' Length
- Custom Lengths from 2.5” to 120” (in 1/2” increments)
- Custom Lengths from 6.4 cm to 305 cm (in 1 cm increments)
Wetted Materials
- 316, 316L Stainless Steel
- Hastelloy C-276
- Titanium Grade 2
Operating Pressure - Sensor
Operating Temperature - Sensor
- -45° to 200° C (-50° to 392° F)
Operating Temperature - Electronics
- -55° to 65° C
- -67° to 149° F
Switch Point Range
- Air & Gases: 0.25 to 200 sfps, 0.08 to 60 smps - Standard Condition 21° C (70° F) at 14.7 psi (1 Atm)
- Hydrocarbon-based Liquids: 0.01 - 5.0 fps, 0.003 - 1.50 mps
- Water-based Liquids: 0.01 - 3.00 fps, 0.003 - 0.9 mps
Response Time
- Approximately 0.5 to 30 seconds
Accuracy
- Flow Service: ± 1.0 % of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
- Level Service: ± 0.64 cm (0.25”)
Switch Type
- 2 SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Max.
Input Power
- 12-24 Vdc, 115-230 Vac, 50/60 Hz / Universal Power Input
- Power Consumption: Max.
Output
- 4-20 mA (Thermal Signal, Scaleable)
Communication
- Modbus RTU Communication-Alarms, Flow Status & Diagnostics
- RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software
Approvals & Certifications
- CRN - Canadian Registration Number - the Kayden Classic 816 does not have a CRN Number
- CSA
- CSA - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Temperature Code: T3 Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
- CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂) Temperature Code: T3
Electronics - Standard Features
- *Configurable only from the Kayden RCM Software
- 100 % Digital Design. Electronics are Environmentally Sealed
- 4-Adjustable Independent Switch Point Timers
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out*
- Easy Setup: No Mechanical Jumpers or Trim Pots
- Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
- Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
- Start-Up Bypass Timer
- Temperature Compensation
- Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode
Remote Control & Monitoring Software
- Adjust Relay Modes
- Adjust Set Points 1 & 2
- Load or Save User Settings
- Lock or Unlock the Display Panel to Protect the Settings
- Many Other Adjustable Features
- Modify Heater Settings to Optimize Response Time
- Monitor Operating Status
- Operated Via a Personal Computer Locally or from a Remote Control Center
- Visualize the Actions of the Process Via the Graphical Display
Local Enclosure Conduit Connection
- 1” NPT Female Conduit Connection
Local Enclosure & Cover Material
- Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)
Local Enclosure Cover
- Buna-N O-Ring on Cover
- Blind Cover - Flameproof
- Glass Lens Cover - Flameproof
Enclosure, Body Details
- 1” NPT Female Conduit Connection
- Buna-N O-Ring on Cover
Local Enclosure & Cover Finish
- Powder-Coated Polyester TGIC
Remote Electronics Enclosure Cover
- Glass Lens Cover - Flameproof
Remote Electronics Enclosure & Cover Finish
- Powder-Coated Polyester TGIC
Storage Temperature
- Store in a clean & dry environment between -30° & 60° C (-22° & 140° F)