Kayden CLASSIC® 816 Flow, Level, Interface Switch & Transmitter

by Kayden

CLASSIC® 816

Request a Quote
Ships 10 - 15 Days

The Kayden CLASSIC 816 Flow, Level and Interface Switch & Transmitter features a precision welded, highly accurate stainless steel sensor.

Ideal for liquids, gases & slurries in a clean or dirty process.

The CLASSIC 816 Retractable Packing Gland is available in a wide range of insertion lengths, with low and medium pressure applications.

All Kayden models feature a rugged flameproof enclosure with blind or lens covers available.

Kayden’s advanced digital electronics will revolutionize the way you monitor and control your process.

  • Process Connection

    • Threaded Retractable Packing Gland (1" MNPT)
  • Adjustable Set Point Range

    • 0-254 feet/s, 0-77 meters/s
  • Insertion 'U' Length

    • Available in 1/2" or 1 cm increments
      Min. 2.5" - Max. 120" (6.0 - 305 cm)
  • Input Power

    • 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum)

    • Determined by Retractable Gland Rating
  • Temperature Range (Sensor)

    • -40°C to 160°C, -40°F to 320°F
  • Local Enclosure

    • Aluminum Flameproof, 1" FNPT Conduit Connection
  • Cover

    • Blind or Glass Lens, Flameproof
  • Wetted Materials

    • 316/316L Stainless Steel
  • Outputs/Communications

    • Two Independent Relays (SPDT), 4-20 mA, Modbus
  • Approvals

    • CSA
    • Single Seal
    • NACE
    • NEMA 4X
The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
read more...
Kayden assembles most products on receipt of order.

20 Models In Stock

816-RAEJ-0060-C1B1B-1E

816-RAEJ-0060-C1B1B-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • J: Retraction Assembly: Low Pressure c/w Retaining Chain, 316 Stainless Steel (MWP 125 psi)
  • 0060: Insertion 'U' Length: 6", 15.2 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 1B: Remote Electronics Enclosure & Cover: Flameproof Blind Cover
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAEJ-0060-C1B1G-1E

816-RAEJ-0060-C1B1G-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • J: Retraction Assembly: Low Pressure c/w Retaining Chain, 316 Stainless Steel (MWP 125 psi)
  • 0060: Insertion 'U' Length: 6", 15.2 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 1G: Remote Electronics Enclosure & Cover: Flameproof Glass Lens Cover
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAEJ-0060-C1G0A1E

816-RAEJ-0060-C1G0A1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • J: Retraction Assembly: Low Pressure c/w Retaining Chain, 316 Stainless Steel (MWP 125 psi)
  • 0060: Insertion 'U' Length: 6", 15.2 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • G: Cover for Local Enclosure: Flameproof Glass Lens Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAEJ-I0060-C1B0A-1E

816-RAEJ-I0060-C1B0A-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • J: Retraction Assembly: Low Pressure, c/w Retaining Chain; 316 Stainless Steel (MWP 125 psi)
  • I0060: Insertion 'U' Length: Custom 6", 15.2 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAEJ-I0860-C1B0A1E

816-RAEJ-I0860-C1B0A1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • J: Retraction Assembly: Low Pressure, c/w Retaining Chain; 316 Stainless Steel (MWP 125 psi)
  • I0860: Insertion 'U' Length: Custom 86", 218.44 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAEJ-M1750-C1G0A-1E

816-RAEJ-M1750-C1G0A-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • J: Retraction Assembly: Low Pressure, c/w Retaining Chain; 316 Stainless Steel (MWP 125 psi)
  • M1750: Insertion 'U' Length: Custom 175 cm, 68.9"
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • G: Cover for Local Enclosure: Flameproof Glass Lens Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAET-0060-C1B0A-1E

816-RAET-0060-C1B0A-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • T: Retraction Assembly: Low Pressure, 316/316L Stainless Steel (MWP 50 psi)
  • 0060: Insertion 'U' Length: 6", 15.2 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAET-0060-C1G0A1E

816-RAET-0060-C1G0A1E

$1,783.00
  • Process Connection: Threaded Retractable Packing Gland (1" MNPT)
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Insertion 'U' Length: 6", 15.2 cm
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Cover
  • Remote Electronics Enclosure and Cover: Not Selected 
  • Wetted Materials:
    • 316 Stainless Steel
  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus
  • UL, CSA, Single Seal, NACE, NEMA 4
816-RAET-0120-C1G0A1E

816-RAET-0120-C1G0A1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • T: Retraction Assembly: Low Pressure, 316 Stainless Steel (MWP 50 psi)
  • I0120: Insertion 'U' Length: Custom 12", 30.5 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • G: Cover for Local Enclosure: Flameproof Glass Lens Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAET-0180-C1B0A-1E

816-RAET-0180-C1B0A-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • T: Retraction Assembly: Low Pressure, 316/316L Stainless Steel (MWP 50 psi)
  • 0180: Insertion 'U' Length: 18", 45.7cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAET-I0480-C1B0A-1E

816-RAET-I0480-C1B0A-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • T: Retraction Assembly: Low Pressure, 316 Stainless Steel (MWP 50 psi)
  • I0480: Insertion 'U' Length: Custom 48", 121.9 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAET-I0480-C1G0A-1E

816-RAET-I0480-C1G0A-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • T: Retraction Assembly: Low Pressure, 316 Stainless Steel (MWP 50 psi)
  • I0480: Insertion 'U' Length: Custom 48", 121.9 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • G: Cover for Local Enclosure: Flameproof Glass Lens Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAET-I0860-C1B0A1E

816-RAET-I0860-C1B0A1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • T: Retraction Assembly: Low Pressure, 316 Stainless Steel (MWP 50 psi)
  • I0860: Insertion 'U' Length: Custom 86", 218.4 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAEX-0060-C1B0A1E

816-RAEX-0060-C1B0A1E

$2,251.00
  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • X: Retraction Assembly: Medium Pressure, 316 Stainless Steel (MWP 500 psi)
  • 0060: Insertion 'U' Length: 6", 15.24 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Microprocessor Controlled with User Interface.
    • Two SPDT sealed relay contacts. Modbus via RS-485.
    • 4-20 mA current loop
816-RAEX-0060-C1B1B-1E

816-RAEX-0060-C1B1B-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • X: Retraction Assembly: Medium Pressure, 316 Stainless Steel (MWP 500 psi)
  • 0060: Insertion 'U' Length: 6", 15.24 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 1B: Remote Electronics Enclosure & Cover: Flameproof Blind Cover
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAEX-0120-C1B0A-1E

816-RAEX-0120-C1B0A-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • X: Retraction Assembly: Medium Pressure, 316 Stainless Steel (MWP 500 psi)
  • 0120: Insertion 'U' Length: 12", 30.5 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAEX-0180-C1B0A-1E

816-RAEX-0180-C1B0A-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • X: Retraction Assembly: Medium Pressure, 316 Stainless Steel (MWP 500 psi)
  • 0180: Insertion 'U' Length: 18", 45.72 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAEX-0240-C1B0A-1E

816-RAEX-0240-C1B0A-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • X: Retraction Assembly: Medium Pressure, 316 Stainless Steel (MWP 500 psi)
  • 0240: Insertion 'U' Length: 24", 60.96 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAEX-0360-C1B0A-1E

816-RAEX-0360-C1B0A-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • X: Retraction Assembly: Medium Pressure, 316 Stainless Steel (MWP 500 psi)
  • 0360: Insertion 'U' Length: 36", 91.44 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
816-RAEX-I0860-C1B0A-1E

816-RAEX-I0860-C1B0A-1E

  • 816-R: Threaded Retractable Packing Gland (1" MNPT)
  • A: Sensor Material: 316/316L Stainless Steel
  • E: Process Connection - Male NPT: 1"
  • X: Retraction Assembly: Medium Pressure, 316 Stainless Steel (MWP 500 psi)
  • I0860: Insertion 'U' Length: Custom 86", 218.44 cm
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
  • E: Language: English
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer

Selected Configuration

816-RAET-I0120-C1B0A-1E

Ships 10 - 15 Days Request a Quote

Configuration

reset configuration

Flow

Ideal Process Conditions

Liquids:

  • Consistent process composition & temperature
  • Sufficient straight run flow profile (minimizes turbulence)
  • Recommended minimum of 5 pipe diameters from any disturbance

Air & Gas:

  • Consistent process composition & temperature
  • Sufficient straight run flow profile (minimizes turbulence)
  • Clean and dry

Slurries:

Emulsion:

  • Consistent process composition & temperature
  • Sufficient straight run flow profile (minimizes turbulence)
  • Consistent process composition & temperature
  • Sufficient straight run flow profile (minimizes turbulence)

Undesirable Process Conditions

Liquids:

  • Inconsistent process composition or temperature
  • Insufficient straight run
  • Turbulence
  • Aerated fluids

Air & Gas:

  • Inconsistent process composition or temperature
  • Wet or saturated air/gas

Slurries:

  • Inconsistent process composition or temperature
  • Insufficient straight run
  • Turbulence
  • Aerated fluids

Emulsion:

  • Inconsistent process composition & temperature
  • Insufficient straight run
  • Turbulence
  • Aerated fluids

Solids:

  • Dry granulated processes are NOT good candidates for thermal switches

Level

Ideal Process Conditions

Liquids:

  • Consistent process composition
  • Non-turbulent

Slurries:

  • Consistent process composition

Emulsion:

  • Consistent process composition

Undesirable Process Conditions

Liquids:

  • Inconsistent process composition
  • Turbulence
  • Large temperature swings

Slurries:

  • Inconsistent process composition
  • Turbulence
  • Large temperature swings

Emulsion:

  • Inconsistent process composition
  • Turbulence
  • Large temperature swings

Solids:

  • Dry granulated processes are NOT good candidates for thermal switches

Interface

Ideal Process Conditions

Liquid to Liquid::

  • Consistent process composition & temperature
  • Non-turbulent applications
  • Large differential in thermal conductivities

Air or Gas to Liquid:

  • Consistent process composition & temperature
  • Non-turbulent applications
  • Dry gas

Emulsion:

  • Consistent process composition & temperature
  • Large differential in thermal conductivities

Undesirable Process Conditions

Liquid to Liquid::

  • Inconsistent process composition or temperature
  • High aeration
  • High turbulence
  • Small differential in thermal conductivities

Air or Gas to Liquid:

  • Inconsistent process composition or temperature
  • High turbulence

Emulsion:

  • Inconsistent process composition or temperature
  • High aeration
  • High turbulence
  • Small differential in thermal conductivities

Solids:

  • Dry granulated processes are NOT good candidates for thermal switches

Flow

  • Pump Protection – Dry Alarm
  • Leak Detection
  • Flow Monitoring & Verification
  • Tank Overflow Protection
  • Flare Gas Monitoring
  • Monitoring Purge Air Flow
  • Lube Oil Systems
  • Vent Monitoring
  • Natural Gas to Boilers
  • Emergency Eye Wash & Shower Stations
  • Drain Line Flow
  • High Pressure Flows
  • Tanker Loading & Unloading
  • Relief Valve & Rupture Disk Flow Monitoring
  • Remote Indication of Flow via Analog Output & Digital Communications
  • Chemical Injection/Additive Flow Monitoring

Level

  • Storage Tanks
  • Oil Separators & Treaters – High, Low & Interface Level
  • Sumps – All Types of fluids ( Water, Oil, etc. )
  • Free Water Knock-out Tanks – High, Low and Interface Level
  • Leak Detection (Accumulation Reservoir)
  • Tank Overflow
  • Sampler Systems
  • Sand Separators

Interface

  • Interface Control in Separation Vessels
  • Interface Detection
  • Interface Control & Level Detection in Settling Vessels

Media

  • Liquids, Air & Gases
  • Hazardous & General-Purpose Areas
  • Slurries
  • Corrosive Liquids

Agency Approvals

  • CRN - Canadian Registration Number - The Kayden Classic 816 does not have a CRN Number


  • CSA - Local (Sensor) Enclosure
    • Flameproof: Class I, Division 1, Groups B, C and D; Ex d IIB + H2
    • AEx d IIB + H2 (Class I, Zone 1, Group IIB + H2)
    • Temperature Code: T3
    • Enclosure Type 4 / IP55
    • Single Seal Approved per ANSI / ISA 12.27.01-2003
  • CSA - Remote Electronics Enclosure - Optional
    • Flameproof: Class I, Groups B, C and D; Ex d IIB + H2
    • AEx d IIB + H2 (Class I, Zone 1, Groups IIB + H2)
    • Temperature Code: T3
  • FM - Local (Sensor) Enclosure
    • Flameproof: Class I, Division 1, Groups B, C and D
    • Temperature Codes: T2D (Ta=75º C); T3 (Ta=65º C)
    • Class I, Zone 1, AEx d IIB + H2
    • Enclosure Type 4 / IP55
  • FM - Remote Electronics Enclosure - Optional
    • Flameproof: Class I, Division 1, Groups B, C and D
    • Temperature Codes: T2D (Ta=75º C), T3 (Ta=65º C)
    • Class I, Zone 1, AEx d IIB + H2
    • Enclosure Type 4 / IP55

Principle of Operation

  • Thermal (Calorimetric)

Environmental Protection

  • NEMA 4 / IP55

Operating Pressure - Sensor

  • Threaded Style: Maximum Available Working Pressure to psig: 3,500 (bar: 241.3, MPa: 24)

Operating Temperature - Electronics

For temperatures above +65° C (+149° F), the electronics must be remotely mounted. 
  • -55° to 65° C (-67° to 149° F)

Operating Temperature - Sensor

  • -45° to 200° C (-50° to 392° F)

Storage Temperature

  • Product should be stored in a clean and dry environment between -30° and 60° C (-22° and 140° F)

Accuracy

  • Flow Service:
    ±1.0% of Set Point Velocity over Operating Range of ±28º C (±50º F)
  • Level Service:
    ±0.64 cm (0.25")

Switch Point Range

  • Gases:
    0.25 to 200 SFPS, 0.08 to 60 SMPS - standard condition 21° C (70° F) at 14.7 psi (1 atm)
  • Hydrocarbon-based Liquids:
    0.01 to 5.0 FPS, 0.003 to 1.50 MPS
  • Water-based Liquids:
    0.01 to 3.00 FPS, 0.003 to 0.9 MPS

Response Time

  • Approximately 0.5 to 30 Seconds

Process Connection - Threaded

  • 1" Male NPT

Insertion 'U' Length

2.5" (6 cm) is standard.
  • Custom 'U' Lengths 2.5" to 120" (6.4 cm to 305 cm) Available in 1/2" (1.0 cm) Increments.

Process Connection Style

  • Threaded Retractable

Switch Type

  • 2 SPDT sealed relay contacts rated @ 4 amps resistive 230 VAC or 30 VDC Max, individually adjustable

Input Power

  • 12-24 Vdc; 115-230 Vac, 50-60 Hz / Universal Power Input
  • Power Consumption: Maximum 4.8 W (Fully Configured)

Communication

  • MODBUS RTU Communication-Alarms, Flow Status and Diagnostics
  • RS-485 using Kayden's Remote Control and Monitoring Software (RCMS) or other Modbus Compatible Software

Output

  • 4-20 mA (Thermal Signal, Scaleable)

Remote Control & Monitoring Software

  • Adjust Relay Modes
  • Adjust Set Points 1 and 2
  • Load or Save User Settings
  • Lock or Unlock the Display Panel to Protect the Settings
  • Many other Adjustable Features
  • Modify Heater Settings to Optimize Response Time
  • Monitor Operating Status
  • Operated via a Personal Computer Locally or from a Remote Control Center
  • Visualize the Actions of the Process via the Graphical Display

Electronics - Standard Features

  • * Only configurable from the Kayden RCM software
  • 100% Digital Design. Electronics are Environmentally Sealed
  • 4-Adjustable Independent Switch Point Timers
  • Automated Redundant Self-Test Diagnostics
  • Display Panel Lock-Out*
  • Easy Setup: No Mechanical Jumpers or Trim Pots
  • Incrementally Adjustable Heater Power (5% steps) with Automatic Over-Range Protection
  • Intelligent User Interface with Push-Button and Constant Display of Operation (Flow/Level)
  • Start-Up Bypass Timer
  • Temperature Compensation
  • Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode

Enclosure/Body Material

  • Copper-Free Aluminum (Does not exceed 0.4% Copper)

Enclosure Finish

  • Powder Coated Polyester TGIC

Enclosure/Body Details

  • 1" Female NPT Conduit Connection
  • Buna-N O-Ring on Cover

Remote Electronics Enclosure & Cover

For temperatures above +65° C (+149° F), the electronics must be remotely mounted.  If cables are required, we recommend the Kayden A06-XP Flameproof Cable & Connector Assembly.

These covers are acceptable for use in hazardous areas.
  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Retraction Assembly

Low pressure, 316 stainless steel is standard.
  • Low Pressure with Security Chain; 316/316L Stainless Steel (MWP 125 psi)
  • Low Pressure; 316/316L Stainless Steel (MWP 50 psi)
  • Medium Pressure; 316/316L Stainless Steel (MWP 500 psi)

Wetted Materials

316/316L stainless steel is standard.
  • 316/316L Stainless Steel
  • All-welded construction
  • Hastelloy® C-276
  • Other metals available
  • Titanium Grade 2

Cover - For Local Enclosure

For local enclosure types below, blind cover is standard.
  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Sensor/Probe Style

  • Insertion

Applications

  • Flow
  • Interface
  • Level

Principal of Operation Details

Kayden sensors incorporate two thin-film platinum Resistance Temperature Detectors (RTDs) and a separate heater element. The Reference RTD senses the actual process condition (as temperature). Heat is applied to the Active RTD by the heater element which is controlled by the microprocessor.

The microprocessor makes continuous comparisons between the temperature readings from the Reference RTD and the Active RTD (values stored as a result of setup programming). As process conditions change, for example increased velocity in a flow application, the Reference RTD “senses” the change and the microprocessor adjusts the heater and changes the relay state if required.

The CLASSIC 800 can be setup with a narrow range to detect very low flows or very small changes in the process, or with a wider range to ignore small fluctuations.

The CLASSIC 800 series switches and transmitters are digital devices and will not require calibration. By design they cannot drift or change in any way unless they suffer physical damage. After correct setup, the CLASSIC 800 will be stable and repeatable under stable process conditions.

The CLASSIC 800 may be setup in the field by the user for flow, level or interface with air, gases, liquids or slurries. The CLASSIC 800 may be setup to display process temperature through the RCM Software while functioning as a flow, level or interface switch/transmitter.

Flow / No Flow
  • When the velocity of the process media is low or nonexistent, less thermal energy (heat) is dissipated from the heated sensor. As the velocity increases the amount of energy dissipated by the process media increases, thereby increasing the Thermal Signal.

    The Thermal Signal is smallest (left-most LED illuminated) in a no-flow state and increases (LED moves to the right) as flow increases.

Liquid Level
  • Air and other gases do not dissipate heat as well as liquids. Therefore, the Thermal Signal is smallest when in a process that does not dissipate heat well (air dissipates heat slower than water).

    The Thermal Signal is smallest (left-most LED illuminated) in a dry, motionless state and increases as the fluid covers the sensor.

Liquid Level / Interface
  • The CLASSIC 800 can be setup to detect the difference between most liquids if there Interface is very little or no velocity and each material has a unique thermal property (for example oil and water in a knockout tank).

A05-GP

Kayden General Purpose Remote Cable

A06-GP

Kayden General Purpose Cable & Connector Assembly

A06-XP

Kayden Flameproof Cable & Connector Assembly

A15-321

Kayden RS232/RS485 Serial Communication Adapter

A15-322

Kayden RS232/USB Adapter

A15-323

Kayden RS485/USB Adapter

Flat Duct Flange

Kayden Flat Duct Flange Mounting Plate

Rolled Duct Flange

Kayden Rolled Duct Flange Mounting Plate