Kayden Instruments Thermal Products
ID: Psw:
partners | 

CMPTM 115

CMP 115

Insertion Style Threaded

All your needs for the CMP 115:
Spec Sheet
CMP Brochure
Product Manual
Dimension Drawings
Wiring Diagrams
Configure
 

Specifications

Applications

  • Flow Switch for Inert Gases 
 

Area Classifications

  • General purpose
 

Material of Construction - Sensor

  • 316L Stainless Steel
 

Process Connections - Threaded

  • 3/4" MNPT (Male National Pipe Thread)
 

Insertion 'U' Lengths

  • Imperial:
    Available insertion lengths include 1.2", 2" and 4"
  • Metric:
    Available insertion lengths include 3 cm, 5 cm and 10 cm
 

Sensor Operating Temperature Range - Continuous Use

  • -40ºC to +75ºC (-40ºF to +167ºF)
 

Operating Pressure - Sensor

  • Maximum Working Pressure: 525 psig (3.6 MPa) at 21ºC (70ºF)
  • Higher ratings available
 

Electronics Operating Temperature Range - Continuous Use

  • -40ºC to +75ºC (-40ºF to +167ºF)
 

Input Power

  • 12-36 VDC
  • Power Consumption: 2.4 watts maximum
 

Electronics - Standard Features

  • Simple control, relay energy status indicated by LED, relay can be NC (normally closed) or NO (normally open) - user selectable
  • LED on indicates power on
 

Outputs

  • Single SPDT sealed relay rated @ 0.5 amp resistive 36 volts AC/DC
 
 

Switch Point Range - Flow

  • Air & Inert Gases:
    0.25 to 125 sfps (0.076 to 38.1 smps) @ 21ºC (70ºF) 1 atm
 

Response Rates

  • 0.5 to 30 seconds.
 

Sensor Enclosure (None)

  • No external enclosure. The electronics are epoxy encapsulated within the sensor housing.
 

Cable Type

  • Thermoplastic Polyurethane (TPU) jacket
  • 10', 30', 50' (3 m, 9 m, 15 m)
 
Configure