Kayden InstrumentsThermal Products
ID: Psw:
partners | 

CMPtm 112

CMP 112

Insertion Style Threaded

All your needs for the CMP 112:
Spec Sheet
CMP Brochure
Product Manual
Dimension Drawings
Wiring Diagrams
Configure
 

Specifications

Applications

  • Flow Switch for Liquids
 

Area Classifications

  • General purpose
 

Material of Construction - Sensor

  • 316L Stainless Steel,all-welded
 

Process Connections - Threaded

  • 3/4" MNPT (Male National Pipe Tapers)
 

Insertion 'U' Lengths

  • Imperial:
    Available insertion lengths include 1.2", 2", 3" and 4"
  • Metric:
    Available insertion lengths include 3cm, 5cm, 7.6cm and 10.1cm
 

Sensor Operating Temperature Range - Continuous Use

  • -40º C to +85º C (-40º F to +185º F)
 

Operating Pressure - Sensor

  • Hydrostatically proof pressure tested to 525 psig (3.6 Mpa) at 21º C (70º F)
  • Higher ratings available
 

Electronics Operating Temperature Range - Continuous Use

  • -40º C to +85º C (-40º F to +185º F)
 

Input Power

  • 12-36 VDC
  • LED on indicates power on
 

Electronics - Standard Features

  • Simple control, relay energy status indicated by LED, relay can be NC (normally closed) or NO (normally open) user selectable
 

Outputs

  • Single SPST sealed relay rated @ 0.5 amp resistive 36 volts AC/DC
 

CMP Control Circuit Features

  • Input Power:
    12-36 VDC
    LED on indicates power on
  • Power Consumption:
    3.9 watts maximum @ 24 VDC
  • Heater Power:
    1.33 watts maximum
  • Relay Rating:
    Single SPST sealed relay rated @ 0.5 amp resistive 36 volts AC/DC
 

Flow Switch Service

  • Water-based Liquids:
    0.01 to 3.0 ft./sec(0.003 to 0.91 meters/sec.)
  • Other Fluids:
    Contact Kayden
  • Lower Flow Rates:
    The CMP is available for low flow rate applications down to 0.04 cc/second in water with installation in a 3/4 inch tee with orifice
 

Level Switch Service

  • Accuracy:
    ±0.25 inch (±0.64 cm)
 

Response Rates

  • 0.5 to 30 seconds. Actual response time depends on the fluid, direction of change and service application.
 

Sensor Enclosure (None)

  • No external enclosure. The electronics are epoxy encapsulated within the sensor housing.
 

Cable Type

  • Standard(longer lengths available)
  • 10 foot (3 m)
  • 4-wire
  • 24 gauge with shield
  • Polyurethane jacket
 
Configure