Kayden Thermal Products
ID: Psw:
partners | 

CLASSICTM 828

CLASSIC 828

Sanitary Flanged

All your needs for the CLASSIC 828:
Spec Sheet
CLASSIC Brochure
Product Manual
Quick Set-Up Guide
FM Approval
UL & CSA Approval
Dimension Drawings
Wiring Diagrams
Application Considerations
Guidelines for Installation
Software
Configure
 

Specifications

Applications

  • Flow, level, interface and temperature
 

Material of Construction - Sensor

  • 304/316 Stainless Steel, Sanitary Finish (3A Compliant)
  • All-welded construction
 

Process Connections - Sanitary type

  • Tri-Clamp Flange
  • Flange size range from 1" to 3.5"
 

Flange Material

  • 304 Stainless Steel
 

Insertion 'U' Lengths

  • Imperial:
    Standard insertion lengths include 2", 3", 4" & 6".
    Custom lengths are available from 2.5" to 120".
  • Metric:
    Standard insertion lengths include 5 cm, 7.5 cm, 10 cm & 15 cm.
    Custom lengths are available from 6.4 cm to 305 cm.
 

Sensor Operating Temperature Range - Continuous Use

  • -45°C to +200°C (-50°F to +392°F)
 

Operating Pressure - Sensor

  • Maximum working pressure 1723 kPa (250 psig) at 70°F (21°C)
 

Electronics Operating Temperature Range - Continuous Use

  • -55°C to +65°C (-67°F to +149°F).
    For temperatures above 75°C (+167°F) remote mounting of electronics is required.
 

Input Power

  • 12-24 VDC; 115-230 VAC, 50-60 Hz
  • Universal Power Input
  • Power Consumption:
    Maximum 4.8 watts (fully configured)
 

Electronics - Standard Features

  • 100% digital design. All electronics are environmentally sealed
  • 4-20 mA output scaled to flow range
  • Intelligent user interface with push-button setup and constant display of operation
  • Temperature compensation
  • Automated redundant self-test diagnostics
  • MODBUS support via RS-485 communications*
  • Easy setup: no mechanical jumpers or trim pots
  • Incrementally adjustable heater power (5% steps) with automatic over-range protection
  • Two independent relays
  • Temperature Mode*: Process temperature may be displayed/graphed in Flow/Level mode
  • 4 adjustable independent switch point timers
  • Display Panel Lock-Out*
  • Start-up Bypass Timer

        * Requires Kayden RCM Software. Available on request.
 

Outputs

 

Communications

  • RS-485 using Kayden's Remote Control & Monitoring Software (RCMS) or other MODBUS compatible software
 

Switch Point Range

  • Water-based Liquids:
    0.01 to 3.00 ft./sec. (0.003 to .9 meters/sec)
  • Hydrocarbon-based Liquids:
    0.01 to 5.0 ft./sec. (0.003 to 1.50 meters/sec)
  • Gases:
    0.25 to 200 SFPS (0.08 to 60 SMPS)
    Standard condition: 21ºC (70ºF) at 14.7 psi (1 atm)
 

Accuracy

  • Flow Service:
    ±1.0% of set point velocity over operating range of ±50ºF (±28ºC)
  • Level Service:
    ±0.25 inches (±0.64 cm)
 

Response Time

  • Approximately 0.5 to 30 seconds.
 

Agency Approvals


Local (Sensor) Enclosure:
  • CSA - Flameproof
    Class I, Div.1, Groups B, C and D; Ex d IIB + H2;
    AEx d IIB + H2 (Class I, Zone 1, Group IIB + H2)
    - T3; Enclosure Type 4 / IP55
    - Single Seal approved per ANSI / ISA 12.27.01-2003
  • FM - Flameproof
    - Class I, Division 1, Groups B, C & D
    - Temperature Codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
    - Class I, Zone 1, AEx d IIB + H2
    - Type 4 / IP55
  • Blind Cover standard
  • Glass Lens Cover optional
  • Enclosure - copper-free aluminum; Powder Coated Polyester TGIC; O-ring on cover.

Remote Electronics Enclosure - Optional:
  • CSA - Flameproof
    - Class I, Div.1+2, Groups B, C eng
    - Class I, Zones 1+2, Groups 11B+H2 , 11A
    - Nema 3, 4, 4x, 7, 9
  • FM - Flameproof
    - Class I, Division 1, Groups B, C & D
    - Temperature Codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
    - Class I, Zone 1, AEx d IIB + H2
    - Type 4 / IP55
  • Blind Cover standard
  • Glass Lens Cover optional
  • One Electronics Module per enclosure; Larger enclosures available 
  • Enclosure - copper-free aluminum; Powder Coated Polyester TGIC; O-ring on cover.
 

Kayden RCMSTM - Optional (Remote Control & Monitoring Software)

  • Operated via a personal computer locally or from a remote control center
  • Monitor operating status
  • Adjust set points 1 & 2
  • Adjust relay modes
  • Modify heater settings to optimize response time
  • Lock or unlock the Display Panel to protect the settings
  • Load or save user settings
  • Visualize the actions of the process via the graphical display
  • Many other adjustable features
 
Configure