Kayden Thermal Products
ID: Psw:
partners | 

CLASSICTM 810

CLASSIC 810

Insertion Style Threaded

All your needs for the CLASSIC 810:
Spec Sheet
CLASSIC Brochure
Product Manual
Quick Set-Up Guide
FM Approval
UL & CSA Approval
CRN Approval
Dimension Drawings
Wiring Diagrams
Application Considerations
Guidelines for Installation
Software
Configure
 

Specifications

Applications

  • Flow, level, interface and temperature
 

Material of Construction - Sensor

  • 316 Stainless Steel, standard
  • Exotic alloys available: Titanium Gr. 2, Hastelloy C-276, Monel 400, Inconel 600, Alloy 20, Nickel 200
  • All-welded construction
 

Process Connections - Threaded

  • 1/2", 3/4", 1", 1 1/4", 1 1/2" and 2" MNPT (Male National Pipe Thread)
 

Insertion 'U' Lengths

  • Imperial:
    Standard insertion lengths include 1.2", 2", 3", 4", 6", 9", 12" & 18".
    Custom lengths are available from 2.5" to 120"
  • Metric:
    Standard insertion lengths include 3 cm, 5 cm, 7.5 cm, 10 cm, 15 cm, 23 cm, 30 cm &  45 cm.
    Custom lengths are available from 6.4 cm to 305 cm
 

Sensor Operating Temperature Range - Continuous Use

  • -45°C to +200°C (-50°F to +392°F)
 

Operating Pressure - Sensor

  • *Maximum working pressure up to 24 MPa (3500 psig) at 21°C (70°F)
  • MWP derated with temperature
  • *Dependent on specific model number
  •  

    Electronics Operating Temperature Range - Continuous Use

    • -55°C to +65°C (-67°F to +149°F).
      For temperatures above 75°C (+167°F) remote mounting of electronics is required.
     

    Input Power

    • 12-24 VDC and 115-230 VAC, 50-60 Hz
    • Universal Power Input
    • Power Consumption:
      Maximum 4.8 watts (fully configured)
     

    Electronics - Standard Features

    • 100% digital design. All electronics are environmentally sealed
    • 4-20 mA output scaled to flow range
    • Intelligent user interface with push-button setup and constant display of operation
    • Temperature compensation
    • Automated redundant self-test diagnostics
    • MODBUS support via RS-485 communications*
    • Easy setup: no mechanical jumpers or trim pots
    • Incrementally adjustable heater power (5% steps) with automatic over-range protection
    • Two independent relays
    • Temperature Mode*: Process temperature may be displayed/graphed in Flow/Level mode
    • 4 adjustable independent switch point timers
    • Display Panel Lock-Out*
    • Start-up Bypass Timer

            * Requires Kayden RCM Software. Available on request.
     

    Outputs

     

    Communications

    • RS-485 using Kayden's Remote Control & Monitoring Software (RCMS) or other MODBUS compatible software
     

    Switch Point Range

    • Water-based Liquids:
      0.01 to 3.00 ft./sec. (0.003 to .9 meters/sec)
    • Hydrocarbon-based Liquids:
      0.01 to 5.0 ft./sec. (0.003 to 1.50 meters/sec)
    • Gases:
      0.25 to 200 SFPS (0.08 to 60 SMPS)
      Standard condition: 21ºC (70ºF) at 14.7 psi (1 atm)
     

    Accuracy

    • Flow Service:
      ±1.0% of set point velocity over operating range of ±50ºF (±28ºC)
    • Level Service:
      ±0.25 inches (±0.64 cm)
     

    Response Time

    • Approximately 0.5 to 30 seconds.
     

    Agency Approvals

    Local (Sensor) Enclosure:
    • CSA - Flameproof
      - Class I, Div.1, Groups B, C and D; Ex d IIB + H2;
      - AEx d IIB + H2 (Class I, Zone 1, Group IIB + H2)
      - T3; Enclosure Type 4 / IP55
      - Single Seal approved per ANSI / ISA 12.27.01-2003
    • FM - Flameproof
      - Class I, Div.1, Groups B, C and D;
      - Class I, Zone 1, AEx d IIB + H2
      - T2D (Ta = 75ºC); T3 (Ta = 65ºC);
      - Enclosure Type 4 / IP55
    • Blind Cover standard
    • Glass Lens Cover optional
    • Enclosure - copper-free aluminum; Powder Coated Polyester TGIC; O-ring on cover.

    Remote Electronics Enclosure - Optional:
    • CSA - Flameproof
      - Class I, Div.1+2, Groups B, C eng
      - Class I, Zones 1+2, Groups 11B+H2 , 11A
      - Nema 3, 4, 4x, 7, 9
    • FM - Flameproof
      - Class I, Division 1, Groups B, C & D
      - Temperature Codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
      - Class I, Zone 1, AEx d IIB + H2
      - Type 4 / IP55
    • Blind Cover standard
    • Glass Lens Cover optional
    • One Electronics Module per enclosure; Larger enclosures available 
    • Enclosure - copper-free aluminum; Powder Coated Polyester TGIC; O-ring on cover.
     

    CRN - Canadian Registration Number

    • 0F09437.125
     

    Kayden RCMSTM - Optional (Remote Control & Monitoring Software)

    • Operated via a personal computer locally or from a remote control center
    • Monitor operating status
    • Adjust set points 1 & 2
    • Adjust relay modes
    • Modify heater settings to optimize response time
    • Lock or unlock the Display Panel to protect the settings
    • Load or save user settings
    • Visualize the actions of the process via the graphical display
    • Many other adjustable features
     
    Configure