| All your needs for the BASIC 432: |
 |
|
| |
Specifications
|
Applications
|
 |
|
| |
Material of Construction - Sensor
|
 |
-
316L Stainless Steel c/w Nickel Braze
|
| |
Process Connections - Flanged
|
 |
-
Raised Face and RTJ (Ring-Type Joint)
-
Flange size and weight range from 3/4" 150# to 10" 2500#
|
| |
Flange Material
|
 |
-
Available in 316L Stainless Steel, Carbon Steel, Monel 400, Nickel, Alloy 20,
Inconel, Hastelloy B, Hastelloy C-276 and Titanium Grade 2
|
| |
Sensor Assembly Body Lengths (Flange Face to Flange Face)
|
 |
-
Imperial:
Custom lengths are available from 7" to 72"
NOTE:7" body length italics not available for all flange sizes.Contact kayden
for information.
-
Metric:
Custom lengths are available from 18cm to 182cm
|
| |
Sensor Operating Temperature Range - Continuous Use
|
 |
-
-55° C to +200° C (-67° F to +392° F)
|
| |
Operating Pressure - Sensor
|
 |
-
Maximum working pressure to flange rating
-
MWP derated with temperature
|
| |
Electronics Operating Temperature Range - Continuous Use
|
 |
-
-55° C to +75° C (-67° F to +167° F).
For temperatures above 75° C (+167° F) remote mounting of electronics enclosure
is required.
|
| |
Input Power
|
 |
-
12-24 VDC; 115-230 VAC, 50-60 Hz
-
Universal Power Input
-
Power Consumption:
Maximum 6 watts
|
| |
Electronics - Standard Features
|
 |
-
Microprocessor based electronics, environmentally sealed
-
Intelligent user interface, constant display of operation (Flow/Level)
-
Temperature compensation
-
Automated redundant self-test diagnostics
-
MODBUS support via RS-485 communications*
-
Variable heater power
* Requires KAYDEN RCM Software.
Available on request.
|
| |
Outputs
|
 |
-
MODBUS registers via RS-485
-
Single SPST sealed relay contact rated @ 5 amps resistive 230 VAC or 24 VDC
|
| |
Communications
|
 |
-
RS-485 using MODBUS compatible software
|
| |
Switch Point Range
|
 |
-
Water-based Liquids:
0.015 to 32cc/sec.(0.015 to 32 ml/sec)
-
Hydrocarbon-based Liquids:
0.033 to 71cc/sec.(0.003 to 71 ml/sec.)
-
Gases:
0.6 to 13,000cc/sec(0.6 to 13 l/sec)
-
Other Fluids:
Contact Kayden
|
| |
Accuracy
|
 |
-
Flow Service:
±0.2% of set point over operating range of ±50° F(±28°C)
-
Level Service:
±0.25 inches(±0.64cm)
-
Repeatability:
±0.5% of reading
1% of full signal range at constant process conditions
|
| |
Response Rates
|
 |
-
Approximately 0.5 to 30 seconds.
|
| |
Agency Approvals
|
 |
Local (Sensor) Enclosure:
-
FM - Flameproof
- Class I, Division 1, Groups C & D
- Temperature codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
- Class I, Zone 1, AEx d IIB
- Type 4/IP55
-
Blind cover standard
-
Lens cover optional
-
Enclosure epoxy coated with O-ring on 8-pin cover
-
Security locking screw for cover
|
 |
Remote Electronics Enclosures - Optional:
-
FM - Flameproof
- Class I, Division 1, Groups C & D
- Temperature codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
- Class I, Zone 1, AEx d IIB
- Type 4/IP55
-
Blind cover standard
-
Lens cover optional
-
One electronics module per enclosure
-
Enclosure epoxy coated with O-ring on 8-pin cover
|
| |
| Configure |
| |
 |