Kayden Thermal Products
ID: Psw:
partners | 

BASIC+TM 430

BASIC 430

In-Line Style Threaded

All your needs for the BASIC+ 430:
Spec Sheet
BASIC Brochure
Product Manual
Quick Set-up Guide
FM Approval
CSA Approval
Dimension Drawings
Wiring Diagrams
Application Considerations
Guidelines for Installation
Software
Configure
 

Specifications

Applications

  • Flow, level and interface
 

Material of Construction - Sensor

  • 316L Stainless Steel c/w Nickel Braze
 

Process Connections - Threaded

  • 3/4" FNPT (Female National Pipe Thread)
  • Optional Injection Tube 3/4" MNPT x 1/4" FNPT
 

Sensor Assembly Body Length

  • In-Line body length is 3.5"(8.8cm)
 

Sensor Operating Temperature Range - Continuous Use

  • -55°C to +200°C (-67°F to +392°F)
 

Operating Pressure - Sensor

  • Maximum working pressure to 3500 psig (24 MPa)
 

Electronics Operating Temperature Range - Continuous Use

  • -55°C to +65°C (-67°F to +149°F).
    For temperatures above 75°C (+167°F) remote mounting of electronics is required.
 

Input Power

  • 12-24 VDC and 115-230 VAC, 50-60 Hz
  • Universal Power Input
  • Power Consumption:
    Maximum 6 watts (fully configured).
 

Electronics - Standard Features

  • Microprocessor based electronics, environmentally sealed
  • Intelligent user interface, constant display of operation (Flow/Level)
  • Temperature compensation
  • Automated redundant self-test diagnostics
  • MODBUS support via RS-485 communications*
  • Variable heater power

        * Requires Kayden RCM Software. Available on request.
 

Outputs

  • MODBUS via RS-485
  • Single SPST sealed relay contact rated @ 5 amps resistive 230 VAC or 24 VDC
 

Communications

  • RS-485 using MODBUS compatible software
 

Switch Point Range - Flow

  • Water-based Liquids:
    0.015 to 32 cc/sec.
  • Hydrocarbon-based Liquids:
    0.033 to 71 cc/sec
  • Gases:
    0.6 to 13,000 cc/sec (0.0006 to 13 l/sec)
 

Accuracy

  • Flow Service:
    ±1.0% of set point velocity over operating range of ±50°F (±28°C)
  • Level Service:
    ±0.25 inches (±0.64cm)
 

Response Time

  • Approximately 0.5 to 30 seconds.
 

Agency Approvals


Local (Sensor) Enclosure:
  • CSA – Flameproof
    - Class I, Division 1, Groups C & D
    - Class I, Zone 1, Group IIB (Ex d IIB & AEx d IIB);
    - T3; Enclosure Type 4 / IP55
    - Single Seal approved per ANSI / ISA 12.27.01-2003
  • FM - Flameproof
    - Class I, Division 1, Groups C & D
    - Temperature Codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
    - Class I, Zone 1, AEx d IIB
    - Type 4/IP55
  • Blind Cover standard
  • Glass Lens Cover optional
  • Enclosure - copper-free aluminum; Powder Coated polyester TGIC; O-ring on spin cover.
  • Security locking screw for cover

Remote Electronics Enclosure - Optional:
  • CSA – Flameproof
    - Class I, Division 1, Groups B, C & D
    - Class I, Zone 1, Group IIB (Ex d IIB & AEx d IIB +H2)
    - Temperature Code: T3
  • FM - Flameproof
    - Class I, Division 1, Groups C & D
    - Temperature Codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
    - Class I, Zone 1, AEx d IIB
    - Type 4/IP55
  • Blind Cover standard
  • Glass Lens Cover optional
  • One electronics module per enclosure
  • Enclosure - copper-free aluminum; Powder Coated polyester TGIC; O-ring on spin cover.
 
Configure