| All your needs for the BASIC+ 430: |
 |
|
| |
Specifications
|
Applications
|
 |
-
Flow, level and interface
|
| |
Material of Construction - Sensor
|
 |
-
316L Stainless Steel c/w Nickel Braze
|
| |
Process Connections - Threaded
|
 |
-
3/4" FNPT (Female National Pipe Thread)
-
Optional Injection Tube 3/4" MNPT x 1/4" FNPT
|
| |
Sensor Assembly Body Length
|
 |
-
In-Line body length is 3.5"(8.8cm)
|
| |
Sensor Operating Temperature Range - Continuous Use
|
 |
-
-55°C to +200°C (-67°F to +392°F)
|
| |
Operating Pressure - Sensor
|
 |
-
Maximum working pressure to 3500 psig (24 MPa)
|
| |
Electronics Operating Temperature Range - Continuous Use
|
 |
-
-55°C to +65°C (-67°F to +149°F).
For temperatures above 75°C (+167°F) remote mounting of electronics is
required.
|
| |
Input Power
|
 |
-
12-24 VDC and 115-230 VAC, 50-60 Hz
-
Universal Power Input
-
Power Consumption:
Maximum 6 watts (fully configured).
|
| |
Electronics - Standard Features
|
 |
-
Microprocessor based electronics, environmentally sealed
-
Intelligent user interface, constant display of operation (Flow/Level)
-
Temperature compensation
-
Automated redundant self-test diagnostics
-
MODBUS support via RS-485 communications*
-
Variable heater power
* Requires Kayden RCM Software.
Available on request.
|
| |
Outputs
|
 |
-
MODBUS via RS-485
-
Single SPST sealed relay contact rated @ 5 amps resistive 230 VAC or 24 VDC
|
| |
Communications
|
 |
-
RS-485 using MODBUS compatible software
|
| |
Switch Point Range - Flow
|
 |
-
Water-based Liquids:
0.015 to 32 cc/sec.
-
Hydrocarbon-based Liquids:
0.033 to 71 cc/sec
-
Gases:
0.6 to 13,000 cc/sec (0.0006 to 13 l/sec)
|
| |
Accuracy
|
 |
-
Flow Service:
±1.0% of set point velocity over operating range of ±50°F (±28°C)
-
Level Service:
±0.25 inches (±0.64cm)
|
| |
Response Time
|
 |
-
Approximately 0.5 to 30 seconds.
|
| |
Agency Approvals
|
 |
Local (Sensor) Enclosure:
-
CSA – Flameproof
- Class I, Division 1, Groups C & D
- Class I, Zone 1, Group IIB (Ex d IIB & AEx d IIB);
- T3; Enclosure Type 4 / IP55
- Single Seal approved per ANSI / ISA 12.27.01-2003
-
FM - Flameproof
- Class I, Division 1, Groups C & D
- Temperature Codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
- Class I, Zone 1, AEx d IIB
- Type 4/IP55
-
Blind Cover standard
-
Glass Lens Cover optional
-
Enclosure - copper-free aluminum; Powder Coated polyester TGIC; O-ring on spin
cover.
-
Security locking screw for cover
|
 |
Remote Electronics Enclosure - Optional:
-
CSA – Flameproof
- Class I, Division 1, Groups B, C & D
- Class I, Zone 1, Group IIB (Ex d IIB & AEx d IIB +H2)
- Temperature Code: T3
-
FM - Flameproof
- Class I, Division 1, Groups C & D
- Temperature Codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
- Class I, Zone 1, AEx d IIB
- Type 4/IP55
-
Blind Cover standard
-
Glass Lens Cover optional
-
One electronics module per enclosure
-
Enclosure - copper-free aluminum; Powder Coated polyester TGIC; O-ring on spin
cover.
|
| |
| Configure |
| |
 |