Kayden InstrumentsThermal Products
ID: Psw:
partners | 

BASIC+tm 428

BASIC 428

Sanitary Flanged

All your needs for the BASIC 428:
Spec Sheet
BASIC Brochure
Product Manual
FM Approval
Dimension Drawings
Acceptable Process Factors
Mounting & Installation
Software
Configure
 

Specifications

Applications

  • Flow, level, and interface
 

Material of Construction - Sensor

  • 304/316L Stainless Steel with Nickel Brazing-Sanitary finish
 

Process Connections - Sanitary type

  • Tri-Clamp Flange
  • Flange size range from 1" to 3.5"
 

Flange Material

  • 304 Stainless Steel
 

Insertion 'U' Lengths

  • Imperial:
    Standard insertion lengths include 2", 3", 4", 6".
  • Metric:
    Standard insertion lengths include 5cm, 7.6cm, 10.1cm, 15.2cm.
 

Sensor Operating Temperature Range - Continuous Use

  • -55° C to +200° C (-67° F to +392° F)
 

Operating Pressure - Sensor

  • Maximum working pressure to flange rating
 

Electronics Operating Temperature Range - Continuous Use

  • -55° C to +75° C (-67° F to +167° F).
    For temperatures above 75° C (+167° F) remote mounting of electronics enclosure is required.
 

Input Power

  • 12-24 VDC; 115-230 VAC, 50-60 Hz
  • Universal Power Input
  • Power Consumption:
    Maximum 6 watts
 

Electronics - Standard Features

  • Microprocessor based electronics, environmentally sealed
  • Intelligent user interface, constant display of operation (Flow/Level)
  • Temperature compensation
  • Automated redundant self-test diagnostics
  • MODBUS support via RS-485 communications*
  • Variable heater power

        * Requires KAYDEN RCM Software. Available on request.
 

Outputs

  • MODBUS registers via RS-485
  • Single SPST sealed relay contact rated @ 5 amps resistive 230 VAC or 24 VDC
 

Communications

  • RS-485 using MODBUS compatible software
 

Flow Switch Service Range

  • Water-based Liquids:
    0.01 to 3.25 fps (0.003 to 0.99 mps)
  • Hydrocarbon-based Liquids:
    0.01 to 5.4 fps (0.003 to 1.64 mps)
  • Gases:
    0.25 to 195 sfps (0.076 to 59 smps)
    SStandard condition: 21º C (70º F) 1 ATM
  • Other Fluids:
    Contact Kayden
  • Lower Flow Rates:
    The BASIC is available for low flow rate applications with the In-Line 430 & 432 models
 

Level Switch Service Range

  • Accuracy:
    ±0.25 inch (±0.64 cm)
  • Repeatability:
    ±0.125 inch (±0.32 cm)
  • Repeatability:
    ±0.05ºF (±0.025ºC)
 

Set Point Accuracy

  • Liquids:
    ±5% of reading (or ±0.04 sfps; ±0.012 smps), whichever is larger
  • Gases:
    ±5% of reading (or ±2 sfps; ±0.6 smps), whichever is larger
  • Repeatability:
    ±0.5% of reading
    1% of full signal range at constant process conditions
 

Response Rates

  • 0.5 to 30 seconds. Actual response time can vary due to fluid type, direction of change and specific application.
 

Agency Approvals


Local (Sensor) Enclosure:
  • FM - Flameproof
    - Class I, Division 1, Groups C & D
    - Temperature codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
    - Class I, Zone 1, AEx d IIB
    - Type 4/IP55
  • Blind cover standard
  • Lens cover optional
  • Enclosure epoxy coated with O-ring on 8-pin cover
  • Security locking screw for cover

Remote Electronics Enclosures - Optional:
  • FM - Flameproof
    - Class I, Division 1, Groups C & D
    - Temperature codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
    - Class I, Zone 1, AEx d IIB
    - Type 4/IP55
  • Blind cover standard
  • Lens cover optional
  • One electronics module per enclosure
  • Enclosure epoxy coated with O-ring on 8-pin cover
 
Configure