| All your needs for the BASIC 416: |
 |
|
| |
Specifications
|
Applications
|
 |
-
Flow, level, and interface
|
| |
Material of Construction - Sensor
|
 |
-
316L Stainless Steel,All-welded,Standard
-
Other exotic alloys available: Titanium Gr. 2, Hastelloy C-276, Monel 400,
Inconel 600, Alloy 20, Nickel 200
-
Pressure Seal-Sensor
|
| |
Process Connections - Threaded Highly Saturated Nitrile
|
 |
-
1" MNPT (Male National Pipe Thread)
|
| |
Pressure Rating - Retractable Packing Gland
|
 |
-
Low pressure; 50 psi
-
Low pressure c/w security chain; 125 psi
-
Medium pressure; 500 psi
|
| |
Insertion 'U' Lengths
|
 |
-
Imperial:
Custom lengths are available from 2.5" to 120"
-
Metric:
Custom lengths are available from 6.0cm to 305cm
|
| |
Sensor Operating Temperature Range - Continuous Use
|
 |
-
-40° C to +160° C (-40° F to +320° F)
|
| |
| |
Electronics Operating Temperature Range - Continuous Use
|
 |
-
-55° C to +75° C (-67° F to +167° F).
For temperatures above 75° C (+167° F) remote mounting of electronics enclosure
is required.
|
| |
Input Power
|
 |
-
12-24 VDC; 115-230 VAC, 50-60 Hz
-
Universal Power Input
-
Power Consumption:
Maximum 6 watts
|
| |
Electronics - Standard Features
|
 |
-
Microprocessor based electronics, environmentally sealed
-
Intelligent user interface, constant display of operation (Flow/Level)
-
Temperature compensation
-
Automated redundant self-test diagnostics
-
MODBUS support via RS-485 communications*
-
Variable heater power
* Requires KAYDEN RCM Software.
Available on request.
|
| |
Outputs
|
 |
-
MODBUS registers via RS-485
-
Single SPST sealed relay contact rated @ 5 amps resistive 230 VAC or 24 VDC
|
| |
Communications
|
 |
-
RS-485 using MODBUS compatible software
|
| |
Switch Point Range
|
 |
-
Water-based Liquids:
0.01 to 3.25 ft./sec. (0.003 to 1.00 meters/sec)
-
Hydrocarbon-based Liquids:
0.01 to 5.4 ft./sec. (0.003 to 1.64 meters/sec.)
-
Gases:
0.25 to 200 std.ft./sec. (0.008 to 60 std.meters/sec.)
Sp Standard condition: 21º C (70º F) at 14.psi(1 ATM)
-
Other Fluids:
Contact Kayden
-
Lower Flow Rates:
The BASIC + is available for low flow rate applications with the In-Line 430
& 432 models
|
| |
Level Switch Service Range
|
 |
-
Accuracy:
±0.25 inch (±0.64 cm)
|
| |
Accuracy
|
 |
-
Flow Service:
±0.2% of Set Point Velocity over operating range of ±50ºF(±28ºC)
-
Level Service:
±0.25 inches(±0.64cm)
-
Repeatability:
±0.5% of reading
1% of full signal range at constant process conditions
|
| |
Response Rates
|
 |
-
Approximately 0.5 to 30 seconds.
|
| |
Agency Approvals
|
 |
Local (Sensor) Enclosure:
-
FM - Flameproof
- Class I, Division 1, Groups C & D
- Temperature codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
- Class I, Zone 1, AEx d IIB
- Type 4/IP55
-
Blind cover standard
-
Lens cover optional
-
Enclosure epoxy coated with O-ring on 8-pin cover
-
Security locking screw for cover
|
 |
Remote Electronics Enclosures - Optional:
-
FM - Flameproof
- Class I, Division 1, Groups C & D
- Temperature codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
- Class I, Zone 1, AEx d IIB
- Type 4/IP55
-
Blind cover standard
-
Lens cover optional
-
One electronics module per enclosure
-
Enclosure epoxy coated with O-ring on 8-pin cover
|
| |
| Configure |
| |
 |