Kayden Thermal Products
ID: Psw:
partners | 

BASIC+TM 412

BASIC 412

Insertion Style Flanged

All your needs for the BASIC+ 412:
Spec Sheet
BASIC+ 400 Brochure
Product Manual
Quick Set-up Guide
FM Approval
CSA Approval
Dimension Drawings
Wiring Diagrams
Application Considerations
Guidelines for Installation
Software
Configure
CRN Approval
 

Specifications

Applications

  • Flow, level and interface
 

Material of Construction - Sensor

  • 316L Stainless Steel (Standard)
  • Exotic alloys available: Titanium Gr. 2, Hastelloy C-276, Monel 400, Inconel 600, Alloy 20, Nickel 200
 

Process Connections - Flanged

  • Raised Face and RTJ (Ring-Type Joint)
  • Flange size and weight range from 1 1/2" 150 ANSI to 10" 2500 ANSI
 

Flange Material

  • Available in 316L Stainless Steel, Carbon Steel, Monel 400, Nickel, Alloy 20, Inconel, Hastelloy B, Hastelloy C-276 and Titanium Gr. 2
 

Insertion 'U' Lengths

  • Imperial:
    Custom lengths are available from 2.5" to 120"
  • Metric:
    Custom lengths are available from 6.0 cm to 305 cm
 

Sensor Operating Temperature Range - Continuous Use

  • -55°C to +200°C (-67°F to +392°F)
 

Operating Pressure - Sensor

  • Maximum working pressure to Flange rating
 

Electronics Operating Temperature Range - Continuous Use

  • -55°C to +65°C (-67°F to +149°F).
    For temperatures above 75°C (+167°F) remote mounting of electronics is required.
 

Input Power

  • 12-24 VDC and 115-230 VAC, 50-60 Hz
  • Universal Power Input
  • Power Consumption:
    Maximum 6 watts (fully configured).
 

Electronics - Standard Features

  • Microprocessor based electronics, environmentally sealed
  • Intelligent user interface, constant display of operation (Flow/Level)
  • Temperature compensation
  • Automated redundant self-test diagnostics
  • MODBUS support via RS-485 communications*
  • Variable heater power

        * Requires Kayden RCM Software. Available on request.
 

Outputs

  • MODBUS via RS-485
  • Single SPST sealed relay contact rated @ 5 amps resistive 230 VAC or 24 VDC
 

Communications

  • RS-485 using MODBUS compatible software
 

Switch Point Range - Flow

  • Water-based Liquids:
    0.01 to 3.00 ft./sec. (0.003 to .9 meters/sec)
  • Hydrocarbon-based Liquids:
    0.01 to 5.0 ft./sec. (0.003 to 1.50 meters/sec)
  • Gases:
    0.25 to 200 SFPS (0.08 to 60 SMPS)
    Standard condition: 21ºC (70ºF) at 14.7 psi (1 atm)
 
 

Accuracy

  • Flow Service:
    ±1.0% of set point velocity over operating range of ±50ºF (±28ºC)
  • Level Service:
    ±0.25 inches (±0.64 cm)
 

Response Time

  • Approximately 0.5 to 30 seconds.
 

Agency Approvals


Local (Sensor) Enclosure:
  • CSA – Flameproof
    - Class I, Division 1, Groups C & D
    - Class I, Zone 1, Group IIB (Ex d IIB & AEx d IIB);
    - T3; Enclosure Type 4 / IP55
    - Single Seal approved per ANSI / ISA 12.27.01-2003
  • FM - Flameproof
    - Class I, Division 1, Groups C & D
    - Temperature Codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
    - Class I, Zone 1, AEx d IIB
    - Type 4/IP55
  • Blind Cover standard
  • Glass Lens Cover optional
  • Enclosure - copper-free aluminum; Powder Coated polyester TGIC; O-ring on spin cover.
  • Security locking screw for cover

Remote Electronics Enclosure - Optional:
  • CSA – Flameproof
    - Class I, Division 1, Groups B, C & D
    - Class I, Zone 1, Group IIB (Ex d IIB & AEx d IIB +H2)
    - Temperature Code: T3
  • FM - Flameproof
    - Class I, Division 1, Groups C & D
    - Temperature Codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
    - Class I, Zone 1, AEx d IIB
    - Type 4/IP55
  • Blind Cover standard
  • Glass Lens Cover optional
  • One electronics module per enclosure
  • Enclosure - copper-free aluminum; Powder Coated polyester TGIC; O-ring on spin cover.
 

CRN - Canadian Registration Number

  • 0F09437.125
 
Configure