Kayden InstrumentsThermal Products
ID: Psw:
partners | 

BASIC+tm 410

BASIC 410

Insertion Style Threaded

All your needs for the BASIC 410:
Spec Sheet
BASIC+ 400
Product Manual
FM Approval
CSA Approval
Dimension Drawings
Acceptable Process Factors
Mounting & Installation
Software
Configure
 

Specifications

Applications

  • Flow, level, and interface
 

Material of Construction - Sensor

  • 316L Stainless Steel, All-welded,Standard
  • Other exotic alloys available: Titanium Gr. 2, Hastelloy C-276, Monel 400, Inconel 600, Alloy 20, Nickel 200
  • 316L Stainless Steel W/Nickel Brazing(1/2" MNPT Only)
 

Process Connections - Threaded

  • 1/2",3/4", 1", 1 1/4", 1 1/2" and 2" MNPT (Male National Pipe Thread)
 

Insertion 'U' Lengths

  • Imperial:
    Standard insertion lengths include 1.2", 2", 3", 4", 6".
    Custom lengths are available from 2.5" to 120"
  • Metric:
    Standard insertion lengths include 3cm, 5cm, 7.6cm, 10.1cm, 15.2cm.
    Custom lengths are available from 6.0cm to 305cm
 

Sensor Operating Temperature Range - Continuous Use

  • -55° C to +200° C (-67° F to +392° F)
 

Operating Pressure - Sensor

  • Maximum working pressure to 3500 psig (24 Mpa) at 21° C (70° F)
  • MWP derated with temperature
  • Higher ratings available
 

Electronics Operating Temperature Range - Continuous Use

  • -55° C to +75° C (-67° F to +167° F).
    For temperatures above 75° C (+167° F) remote mounting of electronics enclosure is required.
 

Input Power

  • 12-24 VDC; 115-230 VAC, 50-60 Hz
  • Universal Power Input
  • Power Consumption:
    Maximum 6 watts
 

Electronics - Standard Features

  • Microprocessor based electronics, environmentally sealed
  • Intelligent user interface, constant display of operation (Flow/Level)
  • Temperature compensation
  • Automated redundant self-test diagnostics
  • MODBUS support via RS-485 communications*
  • Variable heater power

        * Requires KAYDEN RCM Software. Available on request.
 

Outputs

  • MODBUS registers via RS-485
  • Single SPST sealed relay contact rated @ 5 amps resistive 230 VAC or 24 VDC
 

Communications

  • RS-485 using MODBUS compatible with Kayden's RCM software
 

Switch point Range

  • Water-based Liquids:
    0.01 to 3.25 ft./sec. (0.003 to 1.00 meters/sec)
  • Hydrocarbon-based Liquids:
    0.01 to 5.4 ft./sec. (0.003 to 1.64 meters/sec)
  • Gases:
    0.25 to 200 std.ft./sec. (0.08 to 60 std.meters/sec.)
    Sp Standard condition: 21º C (70º F) at 14.7 psi(1 ATM)
  • Other Fluids:
    Contact Kayden
  • Lower Flow Rates:
    The BASIC+ is available for low flow rate applications with the In-Line 430 & 432 models
 

Level Switch Service Range

  • Accuracy:
    ±0.25 inch (±0.64 cm)
 

Accuracy

  • Flow Service:
    ±0.2% of set point velocity over operating range of ±50ºF(±28ºC)
  • Level Service:
    ±0.25 inches(±0.64cm)
  • Repeatability:
    ±0.5% of reading
    1% of full signal range at constant process conditions
 

Response Rates

  • Approximately 0.5 to 30 seconds.
 

Agency Approvals


Local (Sensor) Enclosure:
  • FM - Flameproof
    - Class I, Division 1, Groups C & D
    - Temperature codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
    - Class I, Zone 1, AEx d IIB
    - Type 4/IP55
  • CSA – Flameproof
    - Class I, Division 1, Groups C & D
    - Class I, Zone 1, Group IIB (Ex d IIB & AEx d IIB); T3
  • Blind cover standard
  • Lens cover optional
  • Enclosure epoxy coated with O-ring on 8pin cover
  • Security locking screw for cover

Remote Electronics Enclosures - Optional:
  • FM - Flameproof
    - Class I, Division 1, Groups C & D
    - Temperature codes: T2D (Ta=75ºC), T3 (Ta=65ºC)
    - Class I, Zone 1, AEx d IIB
    - Type 4/IP55
  • CSA – Flameproof
    - Class I, Division 1, Groups B, C & D
    - Class I, Zone 1, Group IIB (Ex d IIB & AEx d IIB +H2)
    - Temperature Code: T3
  • Blind cover standard
  • Lens cover optional
  • One electronics module per enclosure
  • Enclosure epoxy coated with O-ring on 8pin cover
 
Configure