Kayden Corporate
ID: Psw:
partners | 

Compare of Thermal Interface Switches

Processes
Price Range
Sensing Element
Electronics
Input Power
Outputs
Control Circuit Features
Communications
User Interface
Area Classifications
Enclosure Cover
Enclosure
FEATURES MODEL
Processes CLASSIC
800
Series
BASIC+
400
Series
Liquids
Gases
Slurries
Interface
Air & Inert Gas
Price Range CLASSIC
800
Series
BASIC+
400
Series
$ = low, $$$$$ = high $$$$ $$$
Sensing Element CLASSIC
800
Series
BASIC+
400
Series
No moving parts
All-welded sensing elements
Wetted Materials:    
316L Stainless Steel (Std.)
Exotic alloys
Process Connections:    
Insertion lengths - standard
Insertion lengths - custom
1/4" & 1/2" MNPT
3/4", 1", 1¼", 1½" & 2" MNPT
3/4" MNPT Only    
Flanges 1½" ANSI 150 to 10" ANSI 2500
Retractable packing gland assemblies
(1" MNPT and flanges)
Sensors' Process Temperature Range:    
-55°C to +200°C (-67°F to +392°F)
-40°C to +75°C (-40°F to +167°F)    
Maximum Working Pressure:    
3500 psig (24 Mpa) @ 70°F derated with temperature
525 psig (3.6 Mpa) @ 70° F derated with temperature    
Electronics CLASSIC
800
Series
BASIC+
400
Series
Microprocessor based electronics
Self-test diagnostics
4-20 mA analog current loop output  
Adjustable relay mode, higher or lower than setpoint
Selectable temperature mode for relay outputs  
Adjustable set point delay timers  
Front panel lock-out via remote software
Remote electronics available
Input Power CLASSIC
800
Series
BASIC+
400
Series
12-24 VDC and 115-230 VAC, 50 to 60 Hz
12-36 VDC    
Outputs CLASSIC
800
Series
BASIC+
400
Series
Dual SPDT sealed relays, contacts rated @ 5 amps resistive 230 VAC or 24 VDC maximum  
Single SPST sealed relay  
Single SPDT sealed relay    
4-20 mA current loop - (Thermal Signal Scaleable)  
Power Consumption CLASSIC
800
Series
BASIC+
400
Series
Power consumption - 4.8 watts maximum  
Power consumption - 6 watts maximum  
Power consumption - 2.4 watts maximum    
Heater Power:    
Field selectable to optimize switching performance & rangeability.
Communications CLASSIC
800
Series
BASIC+
400
Series
MODBUS support
RS-485
User Interface CLASSIC
800
Series
BASIC+
400
Series
Local interactive interface (via front panel)
Remote interactive interface via software
(set-up / monitoring)
Visual indicators (LED's)
Area Classification CLASSIC
800
Series
BASIC+
400
Series
Flameproof (hazardous location)
General purpose    
Enclosure Cover CLASSIC
800
Series
BASIC+
400
Series
Glass lens (flameproof) provides convenient viewing
Blind cover (flameproof)
Cover locking screw (lens & blind covers)