Cables & Connectors |
 |
| Kayden's cables are used to connect remote sensors to remote electronics. Kayden offers
jacketed cable for both hazardous and general purpose locations. Cables and cable fittings are pre-assembled
and fitted at Kayden's factory to ensure integrity of all connections.
|
| |
 |
 |
Interconnecting Cable - M12 x 1 Socket |
 |
Includes one (1) M12 x 1 socket. Length: 5 meters (16.4 feet) Part Number: A05-M12x1-5M |
 |
Includes one (1) M12 x 1 socket. Length: 10 meters (32.8 feet) Part Number: A05-M12x1-10M |
|
 |
 |
 |
General Purpose Cable |
 |
Assembly includes heat shrink with crimp ferrules. Cable extra. Cable specifications:
Construction: 8 color coded conductors 20 AWG, shielded cable.
Voltage Rating: 30 volts RMS
Temperature Rating: 80° C to -20° C
Part Number: A05-GP-xxxx
|
|
 |
 |
 |
General Purpose Cable & Connector Assembly |
 |
Instrumentation cable comes with two (2) general purpose Thomas & Betts Star Tech Extreme cable fitting.
Cable extra. Cable specifications:
Construction: 7-strand concentric, Class B tinned copper, .020" PVC insulation, individual and over all foil shield, color & number coded,
drain and Mylar separator, PVC inner jacket aluminum interlock armour, PVC out jacket.
Voltage Rating: 300 volts
Temperature Rating: 90° C to -40° C; insulation rated @ 105° C
Part Number: A06-GP-xxxx
|
|
 |
 |
 |
Flameproof Cable & Connector Assembly |
 |
Instrumentation cable comes with two (2) factory sealed hazardous location Thomas & Betts Star Teck XP cable fitting. Assembly includes 2 sealed XP cable fittings,
and sealing compound. Cable extra. Cable specifications:
Construction: 7-strand concentric, Class B tinned copper, .020" PVC insulation, individual and over all foil shield, color & number coded,
drain and Mylar separator, PVC inner jacket aluminum interlock armour, PVC out jacket.
Voltage Rating: 300 volts
Temperature Rating: 90° C to -40° C; insulation rated @ 105° C
Specifications: CSA Standard C22.2: No. 239, #174 Hazardous Locations, #0.3 Clause 4.31, low acid gas. Multiple shielded pairs meet the CSA "HLX" explosion test; FT4 flame test; IEEE-383 low flame spread.
Part Number: A06-XP-xxxx
|
|
 |
 |
 |
General Purpose Connector - T&B STE |
 |
| Star Teck Extreme fittings perform in the harshest and most corrosive environments. Pulp and paper mills, mining,
power utilities, chemical and food processing plants, petro-chemical facilities and more. Star Teck Extreme is ideally suited for any
application where equipment relies heavily on the integrity of electrical connections.
|
 |
Certifications: - Suitable for Class I, Div 2 - NEMA 4, 4X, 6P
Part Number: A25-5001
|
|
 |
 |
 |
Flameproof Connector - T&B STEX |
 |
| The Star Teck STEX series is specially designed for (classified) hazardous areas, and to stand up the harshest and most corrosive environments.
Pulp and paper mills, mining, power utilities, chemical and food processing plants, petro-chemical facilities and more. Star Teck STEX is ideally suited for any
application where equipment relies heavily on the integrity of electrical connections.
|
 |
Certifications: - Ordinary location - Class I, Div 1, Groups A,B,C, D - Class II, Div 1, Groups E, F, G
- NEMA 4, 4X, 6P May be used in hazardous areas with approved MC type cable (or equal) when installed in accordance with NEC/CEC requirements. Part Number: A25-5002
|
|
 |
 |
|